TPU 90A Powder Overview

TPU 90A Powder combines high elongation, tear resistance, and 90A Shore hardness for flexible prototypes and durable end-use parts.

Why TPU 90A

  • Flexible 90A elastomer for resilient parts that bend, compress, cushion, or grip
  • High X/Y elongation and strong tear resistance for demanding functional applications
  • Support-free SLS processing enables complex flexible geometry and production nesting
  • Biocompatibility screening supports evaluation for selected skin-contact applications

Best Fit Applications

Use CaseTypical Examples
Wearables and soft touchWearable interfaces, flexible covers, grips, and soft-touch elements
Sealing and flowGaskets, seals, masks, belts, plugs, and tubes
Impact and vibrationPadding, dampers, cushions, grippers, and protective sports equipment
Human supportSoles, splints, orthotics, and prosthetic components

Material Properties

PropertyMetricImperialMethod
Ultimate tensile strength X/Y8.7 MPa1,260 psiASTM D412-16 Method A
Ultimate tensile strength Z7.2 MPa1,050 psiASTM D412-16 Method A
Elongation at break X/Y310%310%ASTM D412-16 Method A
Elongation at break Z110%110%ASTM D412-16 Method A
Stress at 50% elongation X/Y6.1 MPa889 psiASTM D412-16 Method A
Stress at 50% elongation Z5.9 MPa860 psiASTM D412-16 Method A
Stress at 100% elongation X/Y7.2 MPa1,050 psiASTM D412-16 Method A
Stress at 100% elongation Z7.0 MPa1,020 psiASTM D412-16 Method A
Tear resistance X/Y66 kN/m378 lb/inASTM D624-00 2020
Tear resistance Z39 kN/m247 lb/inASTM D624-00 2020
Compression set at 23 °C20.5%20.5%ASTM D395-18 Method B
Compression set at 70 °C59.9%59.9%ASTM D395-18 Method B
Shore hardness90A90AASTM D2240-15 2021
Taber abrasion122 mm30.007 in3ISO 4649 40 rpm 10 N
Vicat softening temperature94.3 °C201.7 °FASTM D1525
Powder moisture content0.19%0.19%ISO 15512 Method D
Printed-part water absorption0.89%0.89%ASTM D570
Sintered bulk density1.14 g/cm371.2 lb/ft3In-house method

Biocompatibility Screening

Samples printed with TPU 90A Powder were evaluated in accordance with ISO 10993-1:2018. The source testing reported the following outcomes. These results do not establish that a finished device or application is biocompatible; the manufacturer remains responsible for application-specific validation.

StandardAssessmentReported Result
ISO 10993-5:2009CytotoxicityNon-cytotoxic
ISO 10993-23:2021IrritationNon-irritant
ISO 10993-10:2021SensitizationNon-sensitizer

Solvent Compatibility

Percent weight gain after a printed 1 x 1 x 1 cm cube was immersed for 24 hours. A negative value indicates measured weight loss.

SolventGain %
Acetic acid 5%1.3
Acetone28.6
Isopropyl alcohol4.8
Bleach approximately 5% NaOCl0.8
Butyl acetate16.5
Diesel fuel2.0
Diethylene glycol monomethyl ether14.4
Hydraulic oil2.8
Skydrol 56.5
Hydrogen peroxide 3%1.0
Isooctane gasoline surrogate0.7
Mineral oil light2.3
Mineral oil heavy2.1
Salt water 3.5% NaCl0.9
Sodium hydroxide solution pH 100.9
Water0.9
Xylene20.8
Strong acid concentrated HCl-5.2
TPM9.9

Interpreting Compatibility Results

Process and Material Notes

Formlabs reports equivalent Fuse 1 and Fuse 1+ 30W results within experimental uncertainty. The 20% refresh rate supports a blend containing 20% fresh powder and 80% reclaimed powder, subject to the manufacturer’s process instructions and powder-management requirements.

Design and Validation Considerations

  • Account for anisotropy: published elongation is 310% in X/Y and 110% in Z, while tear resistance is 66 kN/m in X/Y and 39 kN/m in Z.
  • Consider compression set and temperature together when designing seals, cushions, and components under sustained strain.
  • Specify functional dimensions, hardness, surface requirements, sealing interfaces, and inspection criteria during application review.
  • Test the final geometry after all cleaning and post-processing, especially for repetitive flexing, chemical contact, skin contact, or safety-critical use.

Data Provenance